If Back-flush and Re-gen are done together, perform the Back-flush process first.

Back-Flush Instructions for Standard Water Softeners

Back flush your Standard Softener every 3 months for 2-5 minutes.

Step 1: Turn off water and disconnect both inlet and outlet hoses. 
Step 2: Use the female/female adapter (not labeled) to the outlet of the softener. 
Step 3: Connect the water source to the softener outlet. 
Step 4: Turn the water on full stream. (If the flow completely stops, turn the water off, tap the tank against the ground to get the resin to fall back down, and turn the water on 75% full stream.) 
Step 5: After the recommend amount of time, turn the water off and hook the softener back up.

Back-Flush Instructions for Double Standard Water Softeners

Back flush your Double Standard Softener every 3 months for 5-10 minutes.

Step 1: Turn off water and disconnect both inlet and outlet hoses. 
Step 2: Use the female/female adapter (not labeled) to the outlet of the softener. 
Step 3: Connect the water source to the softener outlet. 
Step 4: Turn the water on full stream. (If the flow completely stops, turn the water off, tap the tank against the ground to get the resin to fall back down, and turn the water on 75% full stream.) 
Step 5: After the recommend amount of time, turn the water off and hook the softener back up.

Back-Flush Instructions for Park Model Water Softeners

Back flush your Park Model Softener every 3 months for 10-15 minutes.

Step 1: Turn off water and disconnect both inlet and outlet hoses. 
Step 2: Use the female/female adapter (not labeled) to the outlet of the softener. 
Step 3: Connect the water source to the softener outlet. 
Step 4: Turn the water on full stream. (If the flow completely stops, turn the water off, tap the tank against the ground to get the resin to fall back down, and turn the water on 75% full stream.) 
Step 5: After the recommend amount of time, turn the water off and hook the softener back up.